Rockwool Blanket With Wire Mesh
Wired Mesh Covered Rockwool Rock Basalt Wool Blankets are high density thermal and acoustic insulation produced from mineral rock fibers spun from molten basalt and stitched to 25 mm galvanized or stainless steel hexagonal wire mesh according to ASTM C-592 requirements.
UGC Rockwool Wire Mesh Blankets offer superior thermal and acoustic insulation tailored for heavy industrial applications facing intense heat and vibration. These high-density blankets are produced from mineral rock fibers spun from molten basalt, meticulously stitched onto a 25 mm galvanized or stainless steel hexagonal wire mesh, aligning with ASTM C-592 specifications.
Rock Basalt Wool With Wire Mesh Designed for the insulation of hot air ducts, furnaces, boiler tanks, chimneys, and large-diameter pipes, Saudi Rockwool Wired Blankets ensure optimal thermal insulation, fire safety, and sound insulation in the most demanding environments. They are engineered to withstand severe conditions, making them ideal for flanges and valves in oil refineries, chemical plants, and other industrial settings requiring robust insulation solutions.

Advantages:
- Exceptional thermal and acoustic insulation qualities.
- Durability in severe vibration and high temperature conditions.
- Fire safety compliant, with stable physical and chemical properties over time.
- Environmentally friendly, asbestos-free, and resistant to microbial growth.
- Easy to customize and install, compatible with austenitic steel surfaces.
Key Features and Installation Insights:
- Careful handling and precise cutting ensure the integrity of the blankets during installation.
- Suitable for both horizontal and vertical applications, with mechanical fasteners or wire mesh ensuring secure placement.
- Galvanized steel bands and protective coverings enhance durability and resistance to environmental or mechanical impact.
Customization and Technical Specifications:
Available with a standard 25 mm galvanized hexagonal wire mesh, with options for stainless steel or thicker galvanized mesh upon special request.
Offers excellent thermal conductivity and is rated for maximum use temperatures up to 750°C, with a melting point of 1150°C and a Euro fire classification of A1.
Technicial Datesheet
THICKNESS (MM) | DENSITY(KG/M3) | FACING | ASTM CLASSIFICATION | ||
25~120 | 70-150 | Hexagonal Galvanized Or Stainless Steel Wire Mesh | Type II | ||
DENSITY | 70 -145 (kg/m³) | ASTM C303 | |||
THERMAL CONDUCTIVITY (AT24 ˚c) | 0.034 – 0.035 (W/mK) | EN 12667:2001 ASTM C177 | |||
MAX. USE TEMPERATURE |
| ASTM C411 | |||
RIGIDITY | Flexible | ASTM C1101 | |||
COLOR | Yellowish | Visual | |||
SHOT CONTENT | <25 % (weight %) | ASTM C612 | |||
CORROSIVENESS | Noncorrosive | ASTM C871 ASTM C795 | |||
WATER VAPOR SORPTION | <1 (Weight %) | ASTM C1104 | |||
PH | 7-9 | BS 2972 SEC 22 | |||
FLAME SPREAD INDEX | 0 | ASTM E84 | |||
SMOKE DEVELOPED | 0 | ASTM E84 | |||
FUNGI RESISTANCE | Does not encourage Fungi Growth | ASTM C665 | |||
EURO CLASS FIRE CLASSIFICATION | A1 | EN IS0 13501-1 | |||
NOISE REDUCTION COEFFICIENT (NRC) | 0.75 – 1 | ASTM C423 |